The EJECT command moves a cartridge from a slot to a port.
The EJECT command also moves a cartridge from the PTM of a TL82n
Automated Tape Library system. The EJECT command used this way
does not include a slot specification.
Format (slot to port)
EJECT SLOT slot_number [PORT port_number] [ROBOT robot_name]
Format (PTM to port)
EJECT [ROBOT robot_name] PORT [port_number]
1 – Parameters
slot_number - An integer value indicating the robot slot.
port_number - An integer value indicating the robot port.
robot_name - The name for the media robot.
2 – Examples
The following MRU example ejects a cartridge from slot 20 of
a TL820 Automated Tape Library to the outport:
$ ROBOT EJECT SLOT 20 PORT 1 ROBOT $1$DUA0
The following example ejects a cartridge from the PTM of a TL820
Automated Tape Library to the outport:
$ ROBOT EJECT PORT 1 ROBOT $1$DUA0