The READY command enables the inport door release button on the
TL82n Automated Tape Library system. The READY command allows
you to place a cartridge into the inport prior to issuing the
INJECT command.
Format
READY [port_number] [ROBOT robot_name]
1 – Parameters
port_number - An integer value indicating the robot port.
robot_name - The name for the media robot.
2 – Example
The following MRU example enables the inport of a TL820 Automated
Tape Library:
$ ROBOT READY PORT 0 ROBOT $1$DUA0